Pressure Transducer

Pressure Transducer

TP pressure sensors are specifically designed for critical industrial applications like air conditioning, refrigeration, water and air pressure measurement.

GENERAL FEATURES
Pressure ranges 0 bar to 51 bar
Over pressure (1) 25 bar to 81 bar
Burst pressure (2) 110 bar min | 10,1 MPa min | 1600 psi min
Pressure connection 7/16” 20UNF (Female)
Pressure connection material Brass
Tightening torque Brass, 12 to 16 Nm (depending on pressure port type)
Electrical connection Packard connector
Electrical connection material Polymer
ELECTRICAL FEATURES
Power supply (Vdd) 8…30 Vdc
Maximum output load resistance (Vdd – 8V) / 0,025A Ohm
Output response time < 10ms (typical)
Overvoltage protection +33 Vdc
Reverse voltage protection -28 Vdc
Short circuit protected Yes
PERFORMANCE FEATURES
Operating temperature -40°C to 150°C
Storage temperature -40°C to 150°C
Accuracy ± 0,5% F.S. (Linearity, Hysteresis, Repeatability, (5) max. Calibration. Static error band @25°C)
Total error band (3) ± 1% F.S.(4) max. (0…50°C)
(Over Operating Temperature range) ± 1,5% F.S.(4) max. (-10…80°C)
± 2% F.S. max.(4) (-40…135°C)
Cycle life 10 million F.S.(4) cycles
IP Code: IEC60529 -DIN40050-9
IP67 (with connector female IP67 plugged) or IP67 unplugged
Fluids compatibility HVAC refrigerants, new HFO 1234z, R32 R290, refrigerant and associated oils.
Air, water, oil according proper sealing materials.
(other fluids compatibilities available on request)
Vacuum pressure (referred to refrigerant circuit) 0 bar (abs) | 0 kPa (abs) | 0 psi (abs)
Drop (any axis) 1,5m
Vibration: IEC 60068-2-64:2008
10g (from 5 to 2000Hz)
Shock: IEC 60068-2-27:2008
75g, 11ms
Weight 40 grams typical
Specifications
(1) Overpressure: The absolute maximum rating for pressure which may be safely applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to extremely high pressure may cause permanent damage to the product.
(2) Burst Pressure: The maximum pressure that may be applied to the product without causing leakage of the pressure media. The product should not be expected to function after exposure to any pressure beyond the rated burst pressure. This rating is also the case burst rating of the product.
(3) Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, and thermal hysteresis. Specifi c product data page.
(4) F.S. (Full Scale): MAX output – min output = 16mA
PRODUCT CODES
12.006.00.0000 PT 30B g IP68 3m
12.006.00.0001 PT 50B g IP68 3m
12.006.00.0002 PT 20B g IP68 3m H2O
FC200
FC200

FC200 is a controller designed for speed regulation of electronically commutated fans mounted on finned-pack heat exchangers. It is used in the most diverse application sectors such as agriculture, HVAC, process industry, datacenters.

FC300
FC300

FC300 is an advanced controller designed for regulating the speed of electronic fans mounted on finned heat exchangers. It is used in a wide range of applications such as agriculture, HVAC, process industry, and datacenters.

FC400
FC400

The FC400 is an advanced controller designed to regulate the speed of electronic fans mounted on finned heat exchangers. It is used in a wide range of applications such as agriculture, HVAC, process industry and data centres.